Drivers

The list below shows the PLC drivers currently supported by IGSS. For details about the individual driver, click on the Driver Name. If you don’t find the driver you are looking for, please contact our Sales department.

FT2000 (AlarmNet driver) ID:29

Interface Description IGSS32 offers an interface for connecting to FT2000 and FT2000US equipment using TeleDanmark AlarmNet (TeknikNet) as network provider. The FT2000 and FT2000US equipment – typically used for monitoring and control of remote pumpstations – is connected to AlarmNet as AU terminals. IGSS32 is connected to AlarmNet as VC equipment. Virtual connections using AlarmNet […]

FT2000 (AlarmNet driver) ID:29 Read More »

SAIA-P8 ID:27

Interface Description The IGSS32 Saia P8 communication interface offers connection to all Saia PLCs supporting the P8 protocol. Saia P8 protocol is a point-to-point protocol used to communicate via an asynchronious serial RS-232C interface with external devices such as PCs. The IGSS32 Saia P8 communication driver connects directly to the PGU port. Additional serial ports

SAIA-P8 ID:27 Read More »

DDE Supermax ID:26

Interface Description IGSS32 offers an interface for interfacing to DDE Supermax Supervision and control systems. The interface uses and TELNET connection to run the utility program GVAL on the DDE Supermax system. The GVAL utility program enables the IGSS32 communication interface to read all values stored in the DDE Supermax system. The IGSS32 system polls

DDE Supermax ID:26 Read More »

Allen Bradley RS-linx ID:25

Interface Description IGSS32 offers an interface for connecting to all Allen Bradley equipment supported by the Allen Bradley RSLinx software package.The communication interface makes it possible to connect IGSS32 to the following Allen Bradley processors types: PLC-5® , PLC-2®, PLC-3®, PLC-5/250™ and SLC 500, using a number of different network types.In order to use the

Allen Bradley RS-linx ID:25 Read More »

Siemens L2-FMS ID:24

Interface Description IGSS32 offers an interface for PROFIBUS equipment which supports the FMS protocol. The PROFIBUS (Process Field Bus) standard (DIN 19245) is a high-performance communication system for simple and inexpensive equipment. Its functionality and dat transfer capabilities ensure the transition to high performance networks. The IGSS32 Profibus FMS driver interfaces to the ProfiBoard PC

Siemens L2-FMS ID:24 Read More »

Sabroe&Soeby COMSAB II ID:23

Interface Description IGSS32 offers an interface for connecting to COMSAB II gateways. COMSAB II gives the user access to read and write data in the following SABROE compressor control units: PROSAB II, UNISAB S/R/RT/RTH and UNISAB II. The COMSAB II functions as a gateway, converting from the proprietary HDLC/RS485 protocol, which is used between the

Sabroe&Soeby COMSAB II ID:23 Read More »

Mitsubishi Melsec-A (TCP/IP) ID:22

Interface Description IGSS32 offers a TCP/IP interface for the Mitsubishi Melsec A/AnS type PLC equipment. A standard Ethernet interface board in the PC together with standard Windows TCP/IP protocol stacks enables IGSS32 to communicate with Mitsubishi Melsec A/AnS CPUs equipped with AJ71E71-S3, AJS71E71-Bx-S3 or compatible Ethernet interface modules. The IGSS32 system polls the PLC equipment

Mitsubishi Melsec-A (TCP/IP) ID:22 Read More »